Application of Acrel ACR10R Series with AWT100-4G in PV inverters in India

更新日期:2021-09-28瀏覽:678次

Abstract:

       Solar energy is a rapidly growing energy source in the world and the most easily available renewable energy source. The market share of the use of solar energy to transmit electricity to the grid is still growing. At the same time, grid companies usually require the photovoltaic grid-connected system to be an irreversible power generation system, that is, the electricity generated by the photovoltaic grid-connected system is consumed by the local load. It is self-generated and used. In the grid-connected power generation and energy storage system, with the external environment is constantly changing, in order to prevent the photovoltaic grid-connected system from generating reverse power, the system needs to perform reverse current detection, and regulate the power generation of the system by real-time monitoring of the power signal on the low-voltage outlet side of the distribution transformer power, so as to achieve the anti-backflow function of the photovoltaic grid-connected system. This article introduces the application of ACREL ACR10R and AWT100-4G in a pump industry in India

1. Project Overview

   Indian customers plan to produce inverters by themselves. They need inverters and energy meters for government tender. They need ACR10T to monitor the electricity consumption of the plant equipment and use electricity meters to detect the energy consumption of each device effectively. AWT100-4G use MQTT protocol to connect the platform

2. Technical Parameters

3.Wiring & Installation 

4. Network Topology

5.In conclusion

      ACR10R it has a variety of peripheral interface for user to choose: with RS485 communication interface, MODBUS-RTU protocol can meet the needs of communication network management; The function of “ remote signal" and “ remote control" of circuit breaker switch can be realized with switch quantity input and relay output. The interfaces with switch input and relay output can realize the remote signaling and remote control of the circuit breaker switch. It is very suitable for real-time power monitoring system with an LCD display and the panel buttons to realize the setting and control of parameters for PV inverter system.

Bibliography 

1.Solutions for enterprise micro-grid system    2021.04

 

Contact Us
  • 郵箱:2885080326@qq.com
  • 地址:上海市嘉定區(qū)育綠路253號(hào)

掃一掃  微信咨詢

©2025 安科瑞電氣股份有限公司 版權(quán)所有    備案號(hào):滬ICP備05031232號(hào)-79    技術(shù)支持:智慧城市網(wǎng)    Sitemap.xml    總訪問(wèn)量:227095    管理登陸

電瓶車充電樁禁止非法改裝

主站蜘蛛池模板: 勐海县| 陇川县| 电白县| 郸城县| 乌拉特后旗| 蓬莱市| 韩城市| 濉溪县| 宜黄县| 南岸区| 青海省| 舒城县| 阿尔山市| 黄浦区| 临城县| 临泽县| 阿尔山市| 探索| 奇台县| 微山县| 怀仁县| 大同县| 芒康县| 正阳县| 玉树县| 巨鹿县| 牡丹江市| 白城市| 汉寿县| 中超| 河北区| 大方县| 巴林左旗| 越西县| 新乐市| 额济纳旗| 盘锦市| 乌鲁木齐市| 金湖县| 仁怀市| 长武县|